Factory Authorized Fiber Optic Products & Safety Equipment Sales, Service, Repair and Rentals
POLYWATER KC-16  16-Oz Type KC Aerosol (net wt 14 oz) 02786801920   Case OF 12

POLYWATER KC-16 16-Oz Type KC Aerosol (net wt 14 oz) 02786801920 Case OF 12

Available*
Item # 55460075
Model # KC-16
$1,198.80
Peac Financing financing available. Learn More
Qty:

* Notes on Availability:
If item is in stock, it will ship same day.
Lead times vary, contact us for more info.
(Images may not be of the actual item being sold.)

  • Product Description
  • You Might Also like
  • Recently Viewed
Generic
Class
Group
Type
Manufacturer
LOT
Lubricants
Material and Supplies
Lubricants-Sealants
Lubricant- Greases
Polywater
CA Prop 65 Warning Warning: This product can expose you to chemicals, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov

Product Description

AMERICAN POLYWATER KC-16 16-Oz Type KC™ Aerosol (net wt 16 oz) 02786801920 Case OF 12

KC™ - 16 fluid oz (475 ml) aerosol can

Electrical Cable & Equipment Cleaner Plastics Compatible!



A Fast-Acting Cleaner for Electrical and Electronic Use

KC™ Electrical Cable & Equipment Cleaner replaces CFC and chlorinated solvent cable and contact cleaners. It is fast evaporating, non-flammable, and non-carcinogenic. KC™ Contact Cleaner will not attack or degrade sensitive plastics and will not corrode metals. It is essentially non-conductive.

KC™ Electrical Cable & Equipment Cleaner effectively cleans oxidation, dust, and light oils from electrical equipment. Use KC™ to clean cables, circuit boards, controls, switches, substation relays, etc. It will evaporate from the cleaned surface quickly, leaving no residue.

ADVANTAGES No Flashpoint Fast Evaporating Harmless To Most Plastics Residue-Free

Non-Conductive, Non-Corrosive, Non-Staining, Non-Flammable Not An RCRA-Regulated Hazardous Waste No Chlorinated Solvents SNAP Approved

PHYSICAL PROPERTIES Flashpoint (ASTM D93) Initial Boiling Point Specific Gravity Dielectric Strength (ASTM D877) Relative Evaporation Rate Residue (ASTM D2369) Water Content (ASTM D1533B) Propellant Cleaning Strength None 90°F (32°C) 1.4 21 KV Fast < 100 ppm < 50 ppm HFE Good

USAGE DIRECTIONS/PERFORMANCE

KC™ Electrical Cable & Equipment Cleaner is used to clean cables, contacts, and relays on electrical or electronic equipment. Position nozzle 6 to 8 inches (15 - 20 cms) from the surface. Spray liberally and allow solvent to flush oil and dirt. Use the extension tube for hard to reach areas.

KC™ Electrical Cable & Equipment Cleaner is a slightly stronger solvent than the CFC azeotropes that have been used for many years. It will clean light oils, silicone compounds, and fluorinated greases.

KC™ Electrical Cable & Equipment Cleaner evaporates instantly. Forced air, drying towels, and heat are unnecessary. There is no time lost waiting for it to dry. EVAPORATION RATE KC™ Contact Cleaner Perchloroethylene CFC 113 Odorless Mineral Spirits 250 mg/min. 20 mg/min. 200 mg/min. 0.3 mg/min.

COMPATIBILITY

KC™ Electrical Cable & Equipment Cleaner will not corrode or stain metal parts. It does not tarnish or corrode copper per ASTM D 130 and D 1729.

KC™ Electrical Cable & Equipment Cleaner is compatible with most plastics and elastomers. Tables I and II show the effect of KC™ on various plastics and rubbers. KC™ has less effect on these materials than chlorinated solvents and HCFC 141b.

Testing is based on a soak test described in ASTM D 543. KC™ will temporarily affect some rubber compounds. These rubbers may swell, but should return to their original state after the solvent cleaner has dried. Immersion will affect sensitive materials more than incidental contact of a spray and wipe. It is recommended that all plastic parts, gaskets, seals, and o-rings be tested for specific use and exposure method. REGULATORY

USDA and MSHA approved. TSCA listed in the U.S. and DSL listed in Canada. Ozone Depletion Potential = 0.10 Not listed as a hazardous air pollutant (HAP). Not regulated for ground transportation.

SAFETY

KC™ Electrical Cable & Equipment Cleaner has a low level of toxicity. It is not considered a carcinogen and is quite safe to use. Avoid breathing spray, mist, or vapor. Use with adequate ventilation. Wash hands after use. See MSDS for specific details. STORAGE

KC™ Electrical Cable & Equipment Cleaner containers should be kept cool, dry and away from sources of ignition and oxidizing materials. Do not expose aerosol cans to direct sunlight or temperatures above 120°F (50°C). Do not puncture or incinerate aerosol cans. Aerosol cans are freeze/thaw stable.

AMERICAN POLYWATER KC-16 16-Oz Type KC™ Aerosol (net wt 16 oz) 02786801920 Case OF 12

KC™ - 16 fluid oz (475 ml) aerosol can

Electrical Cable & Equipment Cleaner Plastics Compatible!



A Fast-Acting Cleaner for Electrical and Electronic Use

KC™ Electrical Cable & Equipment Cleaner replaces CFC and chlorinated solvent cable and contact cleaners. It is fast evaporating, non-flammable, and non-carcinogenic. KC™ Contact Cleaner will not attack or degrade sensitive plastics and will not corrode metals. It is essentially non-conductive.

KC™ Electrical Cable & Equipment Cleaner effectively cleans oxidation, dust, and light oils from electrical equipment. Use KC™ to clean cables, circuit boards, controls, switches, substation relays, etc. It will evaporate from the cleaned surface quickly, leaving no residue.

ADVANTAGES No Flashpoint Fast Evaporating Harmless To Most Plastics Residue-Free

Non-Conductive, Non-Corrosive, Non-Staining, Non-Flammable Not An RCRA-Regulated Hazardous Waste No Chlorinated Solvents SNAP Approved

PHYSICAL PROPERTIES Flashpoint (ASTM D93) Initial Boiling Point Specific Gravity Dielectric Strength (ASTM D877) Relative Evaporation Rate Residue (ASTM D2369) Water Content (ASTM D1533B) Propellant Cleaning Strength None 90°F (32°C) 1.4 21 KV Fast < 100 ppm < 50 ppm HFE Good

USAGE DIRECTIONS/PERFORMANCE

KC™ Electrical Cable & Equipment Cleaner is used to clean cables, contacts, and relays on electrical or electronic equipment. Position nozzle 6 to 8 inches (15 - 20 cms) from the surface. Spray liberally and allow solvent to flush oil and dirt. Use the extension tube for hard to reach areas.

KC™ Electrical Cable & Equipment Cleaner is a slightly stronger solvent than the CFC azeotropes that have been used for many years. It will clean light oils, silicone compounds, and fluorinated greases.

KC™ Electrical Cable & Equipment Cleaner evaporates instantly. Forced air, drying towels, and heat are unnecessary. There is no time lost waiting for it to dry. EVAPORATION RATE KC™ Contact Cleaner Perchloroethylene CFC 113 Odorless Mineral Spirits 250 mg/min. 20 mg/min. 200 mg/min. 0.3 mg/min.

COMPATIBILITY

KC™ Electrical Cable & Equipment Cleaner will not corrode or stain metal parts. It does not tarnish or corrode copper per ASTM D 130 and D 1729.

KC™ Electrical Cable & Equipment Cleaner is compatible with most plastics and elastomers. Tables I and II show the effect of KC™ on various plastics and rubbers. KC™ has less effect on these materials than chlorinated solvents and HCFC 141b.

Testing is based on a soak test described in ASTM D 543. KC™ will temporarily affect some rubber compounds. These rubbers may swell, but should return to their original state after the solvent cleaner has dried. Immersion will affect sensitive materials more than incidental contact of a spray and wipe. It is recommended that all plastic parts, gaskets, seals, and o-rings be tested for specific use and exposure method. REGULATORY

USDA and MSHA approved. TSCA listed in the U.S. and DSL listed in Canada. Ozone Depletion Potential = 0.10 Not listed as a hazardous air pollutant (HAP). Not regulated for ground transportation.

SAFETY

KC™ Electrical Cable & Equipment Cleaner has a low level of toxicity. It is not considered a carcinogen and is quite safe to use. Avoid breathing spray, mist, or vapor. Use with adequate ventilation. Wash hands after use. See MSDS for specific details. STORAGE

KC™ Electrical Cable & Equipment Cleaner containers should be kept cool, dry and away from sources of ignition and oxidizing materials. Do not expose aerosol cans to direct sunlight or temperatures above 120°F (50°C). Do not puncture or incinerate aerosol cans. Aerosol cans are freeze/thaw stable.

You Might Also Like

Recently Viewed Items

img transfer pixel