Factory Authorized Fiber Optic Products & Safety Equipment Sales, Service, Repair and Rentals
GREENLEE  CFT-35 CABLE FAULT TESTER PROBE, 35KV 52087362 / 783310555780

GREENLEE CFT-35 CABLE FAULT TESTER PROBE, 35KV 52087362 / 783310555780

Available*
Item # 80014720
Model # 783310555780
$435.08
Peac Financing financing available. Learn More
Qty:

* Notes on Availability:
If item is in stock, it will ship same day.
Lead times vary, contact us for more info.
(Images may not be of the actual item being sold.)

  • Product Description
  • You Might Also like
  • Recently Viewed
CA Prop 65 Warning Warning: This product can expose you to chemicals, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov

Product Description

GREENLEE CFT-35 CABLE FAULT TESTER PROBE, 35KV 52087362 / 783310555780

GREENLEE CFT-35 CABLE FAULT TESTER PROBE, 35KV 52087362 / 783310555780

Cable Fault Tester Probe, 35KV

Cable Fault Tester for Use up to 35kV System Voltages (21kV Phase-to-Ground)

The CFT-35 is for use only with two stick voltmeters for testing leakage current in underground primary voltage cables. The CFT-35 can be used on underground cables with grounded neutrals with a maximum line-to-ground voltage of 21.1kV or maximum line-to-line voltage of 36.6kV. Operation at higher voltages may damage the CFT-35 and provide erroneous test results. The CFT-35 is used with a voltmeter/phaser for testing installed or repaired underground cable prior to energizing it. Only cable with extruded dielectric such as rubber or polyethylene can be tested with the CFT-35. Using the CFT-35 on paper insulated cable may provide erroneous test results caused by higher leakage currents typical for this type of cable.

Specifications Sub Brand HDE Application Cable Fault Testing Model CFT-35 Voltage Rating 35kV Tip Material Brass

You Might Also Like

Recently Viewed Items

img transfer pixel